Tj 9001 installation guide for floor and roof framing with tji 110 210 230 360 and 560 joists.
Fire proection for microlam floor joist.
A load bearing fire resistance test was carried out on a larger lvl beam spanning 4 m in a full size furnace following the iso 834 standard fire curve.
With 1 2 wood structural panels with exterior glue applied at right angles to top of joist or top chord of trusses with 8d nails.
Our most versatile beam solution.
Csg tjcan12 simpson connector guide for trus joist products.
Microllam lvl should only be used in dry interior use applications and should not be pressure treated.
Are there established criteria by which equivalent fire performance can be.
If the suspended ceiling system is fire rated as equivalent to the fire performance of 1 2 inch gypsum on the underside of the i joist framing it is considered an alternative to the fire protection requirements in accordance with the first paragraph in the 2015 irc section r302 13 and 2012 irc section r501 3.
Demonstrating equivalent fire performance.
2009 ibc from table 720 1 3 minimum protection for floor and roof systems the floor construction of item 21 1 1 is wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
Tj 9001p installation guide for tji 110 210 230 360 and 560 joists in punjabi language.
However when a gypsum wall board ceiling is not a viable option roseburg rigidlam laminated veneer lumber lvl with a minimum cross section of 1 1 2 x 9 1 2 may.
The provisions call for installation of inch gypsum board 5 8 inch wood structural panel or other approved material on the underside of floor assemblies of buildings constructed under the irc.
Of the 2012 international residential code irc and thus providing an economical layer of fire protection.
Microllam lvl is engineered from large sheets of veneer laminated together to form a rectangular beam product.
Introduction fire is one of the most unpredictable and dangerous accidents that may occur in our environment.
Can prefabricated wood i joists be used without membrane protection.
Lvl is not suitable for the pressure treatment process due to material density and glue lines.
Tj 9510 installation guide for floor and roof framing with tji s31 s33 and s47 joists east canada.
Charring fire performance ignition laminated veneer lumber lvl 1.
Fire protection of floors first appeared in section r501 3 of the 2012 irc.
Section r302 13 exception 4 of the 2015 irc allows other approved floor assemblies demonstrating equivalent fire performance q.
Each veneer is graded ultrasonically so the veneer mix can be tailored to meet the required design characteristics.